JavaScript is disabled in your browser. Please enable JavaScript to view this website.

Gemini™ XPS and EM Microplate Readers

Gemini™ XPS and EM Microplate Readers

Gemini™ XPS and EM Microplate Readers

Fluorescence detection without filters

Multi-wavelength measurement without filters

The Gemini™ XPS and EM Microplate Readers with dual monochromators provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Multiple-point well scanning optimizes cell-based assay sensitivity. Comparison of relative fluorescence units (RFUs) between samples is allowed by a unique calibration against an internal standard. Temperature-sensitive reactions are monitored with consistent temperature regulation from ambient to 45°C.

  • Eliminate changing out filters

    Eliminate the need for identifying, purchasing, and changing out filters. Dual monochromators provide excitation and emission wavelength selection between 250-850 nm.

  • Measure more accurately

    Well scanning reports fluorescent measurements from a single point in the center of a microplate well to multiple points across a tissue culture well.

  • Avoid losing high signals

    Avoid losing high signals to detector saturation and find the correct reader settings with our patented Auto PMT Optimization System.

 

Features

  • Top-read capability

    The top-reading Gemini XPS Microplate Reader measures fluorescence on a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well-scan modes.

  • Top and bottom-read capability

    The top and bottom-reading Gemini EM Microplate Reader measures fluorescence on a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well-scan modes.

Dimensions
Item Height Range (Metric cm) 34 cm
Item Width Range (Metric cm) 42 cm
Specifications
Microplate Reader Type Fluorescence Reader
Detection/Read Type(s) Endpoint, Kinetic, Spectrum Scan, Well Scan
Fluorescence Intensity Read Time Range (sec) 15 sec
Minimum Fluorescence Intensity Wavelength Range (Metric nm) 250 nm
Maximum Fluorescence Intensity Wavelength Range (Metric nm) 850 nm
Microplate Reader Detector(s) Photomultiplier Tube
Light Source(s) Xenon Flash Lamp
Microplate Size Compatibility 6 well plate, 12 well plate, 24 well plate, 48 well plate, 96 well plate, 384 well plate
Microplate Shaking Mode(s) Linear
Wavelength Bandwidth Range (Metric nm) 9 nm
Wavelength Selection Monochromator tunable in 1 nm increments
Microplate Reader Validation Tool(s) Fluorescence Validation Plate, SoftMax® Pro GxP Software
Includes Validation Tools Yes
Robotics/Automation Compatible Yes
Includes Temperature Control Capability Yes
Minimum Temperature Control Range Added to Ambient Temperature (Metric °C) 4 °C
Maximum Temperature Control Range (Metric °C) 45 °C
Item Depth Range (Metric cm) 42 cm