JavaScript is disabled in your browser. Please enable JavaScript to view this website.

CloneSelect® Imager (CSI and CSI FL)

Molecular Devices Clone Select Imager Image1

Molecular Devices Clone Select Imager Fl Image1

Molecular Devices Clone Select Imager Fl Image2

Molecular Devices Clone Select Imager Image2

Molecular Devices Clone Select Imager Image3

Molecular Devices Clone Select Imager Fl Image3

Molecular Devices Clone Select Imager Fl Image4

Molecular Devices Clone Select Imager Fl Optimize Clonal Outgrowth Workflow

High-speed fluorescence and white light imaging, intelligent data analysis, and monoclonality report generation

Next-generation fluorescent imaging solution for the assurance of monoclonality and automated confluence across diverse cell types

Demonstrating that cell lines are monoclonal – or that a gene was edited as expected – can be a time-consuming and highly-subjective process when relying on conventional technologies. The CloneSelect® Imager and CloneSelect® Imager FL are high-throughput automated solutions for imaging and analyzing mammalian cells. Tracking the formation of a colony from a single cell is effortless as barcoded plates are tracked over time. Automated acquisition and analysis provides accurate, objective, and consistent results.

With high-resolution white light imaging, the CloneSelect Imager provides automated confluence, monoclonality assurance and industry-leading acquisition times with the ability to image a 96-well plate in under two minutes.

The all-new CloneSelect Imager FL features high-contrast multichannel fluorescent and white light imaging that allows for accurate single-cell detection and proof of monoclonality at day 0. Streamline your workflow with comparative confluence assays to identify and verify gene edits.

 

 

Demonstrated IND success

The Monoclonality Report feature streamlines the creation of supporting documentation for regulatory agencies. Reports are automatically generated based on the parameters you select. The Monoclonality Report is an audit-ready document that supports filing for an Investigational New Drug (IND) Application with the FDA. (21 CFR Part 312)

 

Multichannel imaging and automated confluence

Algorithms are optimized for accurate cell detection and address varying cell types and conditions. Publication-ready high-resolution imaging provides automatic confluence analysis and monoclonality assurance.

 

Rapid single-cell confirmation

The imager delivers industry-leading acquisition times, imaging a 96-well plate in as little as two minutes and can verify monoclonality from day zero with fluorescence.

 

White light and fluorescent imaging

Image every well in every plate with rapid acquisition times with label-free white light. Multichannel fluorescence imaging provides additional confidence of monoclonality and comparative confluence assays (red vs green).

 

 

Data tools to accelerate research timelines

The software automatically calculates confluence measurements and generates growth curves, heatmaps, and image montages. Measurements for every well are automatically tracked over time. Streamline multiple steps (imaging, sample tracking, data analysis and report generation) in the cell line development workflow for IND filing.

 

 

Quickly image a variety of plate formats and cell types

Image a 96-well plate in under two minutes. Compatible with adherent or settled suspension cell types such as CHO, HEK, hybridomas, iPSCs, and many other cell types.

 

 

Intelligent analysis with easy-to-use software

The software automatically calculates confluence for each imaging time point. The growth curve, image montage, total growth, and mean rate are generated automatically and are exportable. Guided software user interface allows for simple 1-hour training.

 

 

High-resolution images

High-speed fluorescence and high-resolution white light imaging with accurate detection of single cells including debris. Image visualization and data tracking over multiple days.

 

 

Custom automation options*

The Automation and Customization Team offers a variety of custom services from robotic plate loading to fully automated workstations with liquid handling and incubation. We have built our custom automated work cells with the CloneSelect Imager for iPSC workflows, full assay systems and drug toxicity and characterization research.

 

 

CloneSelect Imager FL

Molecular Devices Clone Select Imager Fl Image2

The CloneSelect workflow you know, now with high contrast multichannel fluorescent imaging that allows for verification of gene edits and proof of monoclonality at day zero.

 

Calculate cell growth curves in every well with multichannel fluorescence and white light imaging across diverse cell types.

Imaging
Software Description Software Dedicated imaging software pre-installed on a high specification PC, Microsoft Windows 10
Camera Sensor Type CMOS
White Light Only Field of View Size (Metric mm) 3.74 x 3.74 mm mm
White Light and Fluorescence Field of View (Metric mm) 3.74 x 3.74 mm mm
Fluorescent Imaging Details Ex /Em: 457 /536 nm for FITC /GFP
Specifications
Clone Screening System Type Single-Cell Imaging
Compressed Air Description N/A
Minimum Operating Pressure (Imperial psi) 3.6 psi
Maximum Operating Pressure (Imperial psi) 5.1 psi
Optimal Operating Pressure (Imperial psi) 4.4 psi
Minimum Operating Volume Rate (Metric L/min) NA L/min
Resources
All
Sorting
Newest
Resources
pdf
CloneSelect Imager and CloneSelect Imager FL | Molecular Devices
CloneSelect® Imager and CloneSelect® Imager FL systems provide a label-free imaging solution for the assurance of monoclonality and automated confluence across diverse cell types.
pdf
High assurance monoclonality for cell line development | Molecular Devices
Overview of the process to ensure monoclonality in cell line development.
pdf
CloneSelect Imager Monoclonality Report Feature | Molecular Devices
Features of the CloneSelect Imager for providing image evidence of monoclonality in cell line development, including report generation and cell line monitoring.
pdf
Imaging, Screening, Selection of Mouse Embryonic Stem Cells | Molecular Devices
Explore non-invasive method for mouse Embrionic Stem Cell culture colony number & growth rate monitoring and identification using specific probes.
pdf
Monoclonality Verification Methods Boosting Cell Line Development | Molecular Devices
Here we present a fluorescent method for identifying monoclonal CHO-S cells using CellTracker Green CMDFA.
pdf
Diverse utility of CloneSelect Imager in label-free applications | Molecular Devices
A variety of label-free imaging applications using the CloneSelect Imager, such as colony formation assays and clonality assessment, are presented.